home *** CD-ROM | disk | FTP | other *** search
/ Spec Disk 1998 Spring 4.0 / Spec Disk 1998 Spring 4.0.iso / text / 08110sdi.txt < prev    next >
Encoding:
Text File  |  1998-06-10  |  14.0 KB  |  396 lines

  1.                          SECTION 08110
  2.  
  3.                      STEEL DOORS AND FRAMES
  4. NOTE ** This section is based on products manufactured by
  5.         members of the Steel Door Institute, which is
  6.         located at the following address:
  7. NOTE **      30200 Detroit Road
  8. NOTE **      Cleveland, Ohio 44145
  9. NOTE **      Telephone 216-899-0010
  10. NOTE **      Fax  216-892-1404
  11. NOTE **
  12. NOTE ** Steel doors and frames that are manufactured
  13.         without deviation from SDI standards offer economy
  14.         of fabrication and compliance with recognized
  15.         standards of quality.  Non-standard units can
  16.         result in added cost and lead time.
  17. NOTE **
  18. NOTE ** Members of the Steel Door Institute manufacture
  19.         standard steel doors and frames in accordance with
  20.         these standards.  Standard-duty, heavy-duty, and
  21.         extra-heavy-duty classifications in flush,
  22.         seamless, glazed, louvered, and other styles are
  23.         available.
  24. NOTE **
  25. NOTE ** SECTION 08110 - STEEL DOORS AND FRAMES, Copyright
  26.         1996, The Architect's Catalog, Inc.
  27.  
  28.  
  29. PART 1  GENERAL
  30.  
  31. 1.1 SECTION INCLUDES
  32. NOTE ** Delete items below not required for project.
  33.  
  34.     A.  Steel doors.
  35.  
  36.     B.  Steel frames.
  37.  
  38. 1.2 RELATED SECTIONS
  39. NOTE ** Delete any sections below not relevant to this
  40.         project;  add others as required.
  41.  
  42.     A.  Section 08210 - Wood Doors.
  43.  
  44.     B.  Section 08220 - Plastic Doors.
  45.  
  46.     C.  Section 08710 - Door Hardware.
  47.  
  48.     D.  Section 08800 - Glazing.
  49.  
  50.     E.  Section 09900 - Paints and Coatings.
  51.  
  52.     F.  Section 13095 - X-Ray Radiation Protection.
  53.  
  54. 1.3 REFERENCES
  55. NOTE ** Delete references from the list below that are not
  56.         actually required by the text of the edited
  57.         section.
  58.  
  59.     A.  ANSI/SDI 100-91 - Recommended Specifications for Standard
  60.         Steel Doors & Frames;  Steel Door Institute.
  61.  
  62.     B.  SDI 105 - Recommended Erection Instructions for Steel
  63.         frames.
  64.  
  65.     C.  SDI 111 - Recommended Standard Details for Steel Doors &
  66.         Frames.
  67.  
  68.     D.  SDI 113 - Test Procedure and Acceptance Criteria for
  69.         Acoustical Performance for Steel Door and Frame
  70.         Assemblies.
  71.  
  72.     E.  ASTM A 366/A 366M - Standard Specification for Steel,
  73.         Sheet, Carbon, Cold-Rolled, Commercial Quality.
  74.  
  75.     F.  ASTM A 568/A 568M - Standard Specification for Steel,
  76.         Sheet, Carbon, and High-Strength, Low-Alloy, Hot-Rolled
  77.         and Cold-Rolled, General Requirements For.
  78.  
  79.     G.  ASTM A 569/A 569M - Standard Specification for Steel,
  80.         Carbon (0.15 Maximum, Percent), Hot-Rolled Sheet and
  81.         Strip Commercial Quality.
  82.  
  83.     H.  ASTM A 591/A 591M - Standard Specification for Steel
  84.         Sheet, Electrolytic Zinc-Coated, for Light Coating Mass
  85.         Applications.
  86.  
  87.     I.  ASTM A 653/A 653M - Standard Specification for Steel
  88.         Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated
  89.         (Galvannealed) by the Hot-Dip Process.
  90.  
  91.     J.  ASTM A 924/A 924M - Standard Specification for General
  92.         Requirements for Sheet Steel, Metallic-Coated by the Hot-
  93.         Dip Process.
  94.  
  95.     K.  NFPA 80 - Standard for Fire Doors and Windows.
  96.  
  97.     L.  Building Materials Directory; Underwriters Laboratories
  98.         Inc.
  99.  
  100.     M.  Certification Listings;  Warnock Hersey International
  101.         Inc.
  102.  
  103. 1.4 SUBMITTALS
  104.  
  105.     A.  Submit under provisions of Section 01300.
  106.  
  107.     B.  Product Data:  Provide manufacturer's standard details
  108.         and catalog data demonstrating compliance with referenced
  109.         standards.  Provide installation instructions.
  110.  
  111.     C.  Certificates:
  112.         1.  Provide manufacturer's certification that products
  113.             comply with referenced standards.
  114.         2.  Provide evidence of manufacturer's membership in the
  115.             Steel Door Institute.
  116.  
  117.     D.  Shop Drawings:  Submit for approval the following:
  118.         1.  Door, frame, and hardware schedule in accordance with
  119.             SDI 111D.
  120. NOTE ** Delete the following paragraph if no factory-
  121.         finished units are required.
  122.  
  123.     E.  Samples:  Submit for approval the following:
  124.         1.  6 x 6 inch samples of each color of factory finish
  125.             specified.
  126.  
  127. 1.5 QUALITY ASSURANCE
  128.  
  129.     A.  Manufacturer Qualifications:  Provide all products from a
  130.         single manufacturer who is a member of the Steel Door
  131.         Institute.
  132.  
  133. 1.6 DELIVERY, STORAGE, AND HANDLING
  134.  
  135.     A.  Protect products from moisture, construction traffic, and
  136.         damage.
  137.         1.  Store under cover.
  138.         2.  Place units on 4-inch high wood sills or in a manner
  139.             that will prevent rust or damage.
  140.         3.  Do not use non-vented plastic or canvas shelters.
  141.         4.  Should wrappers become wet, remove immediately.
  142.         5.  Provide 1/4-inch space between doors to promote air
  143.             circulation.
  144.  
  145.  
  146. PART 2  PRODUCTS
  147.  
  148. 2.1 MATERIALS
  149.  
  150.     A.  Steel Sheet for Doors and Frames:
  151.         1.  Cold rolled steel:  ASTM A 366 and A 568.
  152.         2.  Hot rolled, pickled, and oiled steel:  ASTM A 569 and
  153.             A 568.
  154. NOTE ** Delete the following 2 paragraphs if galvanized
  155.         units are not required.
  156.         3.  Hot dipped zinc coated steel: ASTM A 924 and A 653;
  157.             Class A40 for alloyed coatings or G60 for spangled
  158.             coatings, minimum.
  159.  
  160.     B.  Steel Sheet for Anchors and Accessories:
  161.         1.  Electrolytically deposited zinc coated steel:  ASTM A
  162.             591 and A 568;  Class B (0.075 oz/sf), minimum.
  163.  
  164. 2.2 MANUFACTURED UNITS
  165.  
  166.     A.  Comply with SDI 100.
  167. NOTE ** Delete the following paragraph if fire-rated
  168.         openings are not required.
  169.  
  170.     B.  Fire-rated openings:  Comply with NFPA 80.
  171.         1.  Affix permanent labels attesting to fire resistance.
  172.         2.  At stairway enclosures, provide units listed for 450
  173.             degree F maximum temperature rise rating for 30
  174.             minutes of exposure.
  175. NOTE ** Delete the following paragraph if no oversized
  176.         openings are required.  (Oversized openings are
  177.         units that are larger than commonly fabricated for
  178.         a given fire rating.)  If oversized units are
  179.         required, and if acceptable to the local authority
  180.         having jurisdiction, retain the following
  181.         paragraph.
  182.         3.  Provide manufacturer's certificate that oversized
  183.             openings have been constructed in accordance with all
  184.             other applicable requirements for labeled door
  185.             construction.
  186. NOTE ** Delete the first paragraph below if Grade and Model
  187.         will be specified.
  188. NOTE **
  189. NOTE ** Delete the second paragraph if Grade and Model will
  190.         be in the door schedule.  If the second paragraph
  191.         is retained, edit to suit project conditions;
  192.         specify location of each required Grade and Model
  193.         in the blanks provided.
  194. NOTE **
  195. NOTE ** Grade I and III frames are offered in 2 gages.
  196.         Delete inapplicable gages.
  197. NOTE ** Grade II frames are offered in 16 gage, only.
  198. NOTE **
  199. NOTE ** For additional guidance, see SDI-108 Recommended
  200.         Selection & Usage Guide for Standard Steel Doors.
  201.  
  202.     C.  Provide Grade and Model as indicated in the Door
  203.         Schedule.
  204.  
  205.     D.  Provide Grade and Model as follows:
  206.         1.  ____:  Grade I, Model 1 (standard-duty, full flush
  207.             design).
  208.             a.  Frames:  18 gage.
  209.             b.  Frames:  16 gage.
  210.         2.  ____:  Grade I, Model 2 (standard-duty, seamless
  211.             design).
  212.             a.  Frames:  18 gage.
  213.             b.  Frames:  16 gage.
  214.         3.  ____:  Grade II, Model 1 (heavy-duty, full flush
  215.             design).
  216.         4.  ____:  Grade II, Model 2 (heavy-duty, seamless
  217.             design).
  218.         5.  ____:  Grade III, Model 1 (extra heavy-duty, full
  219.             flush design).
  220.             a.  Frames:  16 gage.
  221.             b.  Frames:  14 gage.
  222.         6.  ____:  Grade III, Model 1A (extra heavy-duty, full
  223.             flush design).
  224.             a.  Frames:  14 gage.
  225.             b.  Frames:  12 gage.
  226.         7.  ____:  Grade III, Model 2 (extra heavy-duty, seamless
  227.             design).
  228.         8.  ____:  Grade III, Model 2A (extra heavy-duty,
  229.             seamless design).
  230.             a.  Frames:  14 gage.
  231.             b.  Frames:  12 gage.
  232.         9.  ____:  Grade III, Model 3 (extra heavy-duty, stile
  233.             and rail - flush panel design).
  234.             a.  Frames:  16 gage.
  235.             b.  Frames:  14 gage.
  236.         10. Wood or plastic doors specified elsewhere:  Provide
  237.             18 gage, Grade I steel frames.
  238.         11. Wood or plastic doors specified elsewhere:  Provide
  239.             16 gage, Grade I steel frames.
  240.         12. Wood or plastic doors specified elsewhere:  Provide
  241.             Grade II steel frames.
  242.         13. Wood or plastic doors specified elsewhere:  Provide
  243.             16 gage, Grade III steel frames.
  244.         14. Wood or plastic doors specified elsewhere:  Provide
  245.             14 gage, Grade III steel frames.
  246. NOTE ** Delete 1 of the 2 following paragraphs if
  247.         galvanized frames are required.  Delete both if
  248.         none are required.  If the second is retained, edit
  249.         to suit project requirements.
  250.  
  251.     E.  Provide units of galvanized steel where indicated on the
  252.         door schedule.
  253.  
  254.     F.  Provide units of galvanized steel in the following
  255.         locations:
  256.         1.  Exterior openings.
  257.         2.  Kitchens.
  258.         3.  Toilets.
  259.         4.  Washrooms.
  260.         5.  Locker rooms.
  261.         6.  Showers.
  262.         7.  Laboratories.
  263. NOTE ** Delete the following paragraph if no lights in
  264.         doors, nor borrowed or side lights are required.
  265.  
  266.     G.  Provide glazing stops and beads where glazed lights are
  267.         indicated.
  268.  
  269. 2.3 DOORS
  270.  
  271.     A.  Construct doors in accordance with SDI 100.
  272. NOTE ** Delete the following paragraph if exterior doors
  273.         are not required.
  274. NOTE **
  275. NOTE ** If retained, delete 2 of the 3 subparagraphs to
  276.         indicate U-value, or edit to suit project
  277.         requirements.
  278.  
  279.     B.  Exterior doors:
  280.         1.  Provide insulated construction with U-value of at
  281.             least 0.48 when tested in accordance with SDI 113.
  282.         2.  Provide manufacturer's standard foam insulated core.
  283.         3.  Steel stiffened grid core and stile and rail units
  284.             are exempt from thermal rating requirements.
  285. NOTE ** SDI-100 allows any core construction complying with
  286.         established physical endurance test criteria.
  287.         Therefore, unless unusual project conditions
  288.         necessitate the specification of core construction,
  289.         the following paragraph may be deleted in its
  290.         entirety.
  291. NOTE **
  292. NOTE ** If retained, edit to suit project requirements.
  293.  
  294.     C.  Construct full flush and seamless door cores as follows:
  295.         1.  Fire-rated doors:  In accordance with listed
  296.             construction.
  297.         2.  Honeycomb core.
  298.         3.  Polyurethane foam core.
  299.         4.  Polystyrene foam core.
  300.         5.  Unitized grid core.
  301.         6.  Steel stiffeners core.
  302. NOTE ** Delete the following paragraph if louvers are not
  303.         required.
  304.  
  305.     D.  Provide inserted louvers in accordance with SDI 111C
  306.         where indicated.  Type:
  307.         1.  Inverted "V" blade.
  308.         2.  "Z" blade.
  309.         3.  Inverted "Y" blade.
  310.         4.  Light proof.
  311.         5.  Adjustable.
  312.         6.  Fusible link.
  313.         7.  Grille.
  314.  
  315. 2.4 FRAMES
  316. NOTE ** Delete 1 of the 2 following paragraphs.
  317.  
  318.     A.  Provide either knockdown field assembled or welded unit
  319.         type frames unless otherwise indicated.
  320.  
  321.     B.  Provide welded unit type frames.
  322. NOTE ** Delete any of the next 3 paragraphs if such units
  323.         are not required.
  324.  
  325.     C.  Provide drywall slip-on type frames for installation
  326.         after drywall partition are erected
  327.  
  328.     D.  Lights and Transoms:  Provide tubular mullions and
  329.         transom bars with heads and jambs.
  330.  
  331.     E.  Terminate stops at a 45 degree angle, 6 inches above
  332.         floor;  cover stop with welded metal filler plate.
  333.         1.  Exception:  Light-proof doors, sound-rated, doors,
  334.             lead-lined doors, and double egress doors.
  335. NOTE ** SDI-100 requires factory priming for field painting
  336.         as a minimum.  Many manufacturers also offer
  337.         factory finishing.
  338. NOTE **
  339. NOTE ** Delete the following article if factory finished
  340.         units are not required.
  341. NOTE **
  342. NOTE ** If retained, edit to indicate color.
  343.  
  344. 2.5 FINISHES
  345.  
  346.     A.  Provide factory-finished units.
  347.         1.  Color:  As indicated on the color schedule.
  348.         2.  Color:  _______.
  349.  
  350.  
  351. PART 3  EXECUTION
  352.  
  353. 3.1 EXAMINATION
  354.  
  355.     A.  The installer shall verify that project conditions are
  356.         suitable before beginning installation of frames.
  357.         1.  Verify that completed openings to receive knock-down
  358.             wrap-around frames are of correct size and thickness.
  359.         2.  Verify that completed concrete or masonry openings to
  360.             receive butt type frames are of correct size.
  361.  
  362.     B.  Correct unsatisfactory condition before preceding with
  363.         installation.
  364.  
  365. 3.2 INSTALLATION
  366.  
  367.     A.  Install frames in accordance with SDI 105.
  368.  
  369.     B.  Install doors plumb and in true alignment and fasten to
  370.         achieve the maximum operational effectiveness and
  371.         appearance of the unit.  Maintain clearances specified in
  372.         SDI 100 or NFPA 80.
  373. NOTE ** Delete any of the 3 following paragraphs if not
  374.         applicable.
  375.  
  376.     C.  Fill welded wrap-around frames in masonry construction
  377.         with mortar as masonry is laid-up.
  378.  
  379.     D.  Fill welded wrap-around frames in plaster construction
  380.         with plaster as work progresses.
  381.  
  382.     E.  If additives are used in masonry or plaster work during
  383.         cold weather, field coat the inside of steel frames with
  384.         a bituminous compound to prevent corrosion.
  385.  
  386. 3.3 ADJUST AND CLEAN
  387.  
  388.     A.  Adjust doors for proper operation, free from binding or
  389.         other defects.
  390.  
  391.     B.  Clean and restore soiled surfaces.  Remove scraps and
  392.         debris, and leave site and a clean condition.